MSK 5973RH RAD Hard Adjustable Negative Linear Regulator Total Dose Radiation Test Report

2022-11-10
●Introduction
■The total dose radiation test plan for the MSK 5973RH series was developed to qualify the devices as RAD Hard to 100 KRADS(Si). The testing was performed beyond 100 KRADS(Si) to show trends in device performance as a function of total dose. The test does not classify maximum radiation tolerance of the device, but simply offers designers insight to the critical parameter-shifts up to the specified total dose level.
■MIL-STD-883 Method 1019.7 and ASTM F1892-06 were used as guidelines in the development and implementation of the total dose test plan for the MSK 5973RH.
●Summary
■Based on the test data recorded during radiation testing and statistical analysis, the MSK5973RH qualified as a 100 Krad(Si) radiation hardened device. Reference Voltage, Line Regulation and Load Regulation exhibited the most significant shift due to irradiation, however all performance curves stayed within specification up to 150 Krad(Si) TID.