MSK5965RH Rad Hard Positive Low Noise LDO Total Dose Radiation Test Report
■The total dose radiation test plan for the MSK5965RH was developed to qualify the devices as Rad Hard to 100 Krad(Si). The testing was performed beyond 100 Krad(Si) to show trends in device performance as a function of total dose. The test does not classify maximum radiation tolerance of the device, but simply offers designers insight to the critical parameter-shifts up to the specified total dose level.
■MIL-STD-883 Method 1019.7 and ASTM F1892-06 were used as guidelines in the development and implementation of the total dose test plan for the MSK5965RH.
●Summary
■Based on the test data recorded during radiation testing and statistical analysis, the MSK5965RH qualified as a 100 Krad(Si) radiation hardened device.
■Load Regulation, Current Limit and Ground Pin Current exhibited the most significant change with irradiation, however all performance curves stayed within post irradiation specifications up to 300 Krad(Si).
|
|