MSK5910RH (MSK5900RH, MSK5920RH, MSK5921RH, MSK5922RH) Ultra Low Dropout Adjustable Positive Linear Regulator Total Dose Radiation Test Report
■The total dose radiation test plan for the MSK5910RH was developed to qualify the device as a radiation tolerant device to 100 Krad(Si). The testing was performed up to 150 Krad(Si) to show trends in device performance as a function of total dose. The MSK5900RH, MSK5910RH, MSK5920RH, MSK5921RH, and MSK5922RH all use the same active components. The data in this report is from direct measurement of the MSK5910RHresponse to irradiation, but it is indicative of the response of all five device types and is applicable to all five types.
■MIL-STD-883 Method 1019.7 and ASTM F1892-06 were used as guidelines in the development and implementation of the total dose test plan for the MSK5910RH.
●Summary
■Based on the test data recorded during radiation testing, the MSK5910RH qualified as a 100 Krad(Si) Radiation Hardened device.
■Based on the test data recorded during radiation testing and statistical analysis, Feedback Voltage, Shutdown Threshold, Shutdown Hysteresis and Output Current Limit exhibited shift due to irradiation, however all performance curves stayed within specification beyond 100 Krad(Si) TID.
MSK5910RH 、 MSK5900RH 、 MSK5920RH 、 MSK5921RH 、 MSK5922RH 、 MSK5910KRH |
|
|
|
Test Report |
|
|
|
Please see the document for details |
|
|
|
|
|
|
|
English Chinese Chinese and English Japanese |
|
August 22,, 2018 |
|
|
|
|
|