MSK5972KRH and MSK5972KRHL RAD Hard Positive Voltage Regulator Total Dose Radiation Test Report
■The Total Ionizing Dose radiation test plan for the MSK5972RH was developed to qualify the devices as RAD Hard to 100Krad(Si). The testing was performed beyond 100Krad(Si) to show trends in the device performance as a function of total dose. The test does not classify maximum radiation tolerance of the device, but simply offers designers insight to the critical parameter-shifts up to the specified total dose level.
■MIL-STD-883 Method 1019.7 and ASTM F1892-06 were used as guidelines in the development and implementation of the total dose test plan for the MSK5972RH.
●Summary
■Based on the test data recorded during radiation testing and statistical analysis, the MSK5972RH qualifies as a 100Krad(Si) radiation hardened device. All performance curves stayed well within specifications up to the maximum test dose, 150Krad(Si) TID.