MSK5983RH RAD Hard Positive Adjustable Voltage Regulator Total Dose Radiation Test Report

2022-11-10
●Introduction
■The total dose radiation test plan for the MSK5934RH was developed to qualify the devices as RAD Hard to 100 KRads(Si). The testing was performed beyond 100 KRads(Si)to show trends in device performance as a function of total dose. The test does not classify maximum radiation tolerance of the device, but simply offers designers insight to the critical parameter-shifts up to the specified total dose level.
■MIL-STD-883 Method 1019.7 and ASTM F1892-06 were used as guidelines in the development and implementation of the total dose test plan for the MSK5983RH.
●Summary
■Based on the test data recorded during radiation testing and statistical analysis, the MSK5983RH qualified as a 100 Krad(Si) radiation hardened device. The Set Pin Currents exhibited the most significant change with irradiation, however all performance curves stayed within specification up to 450 Krad(Si) TID.