MSK 5977RH (MSK5953RH, MSK5976RH, MSK5979RH) RAD Hard Positive Adjustable Voltage Regulators Total Dose Radiation Test Report

2022-11-10
●Introduction
■The total dose radiation test plan for the MSK 5977RH was developed to qualify the devices as RAD Hard to 300 KRADS(Si). The testing was performed beyond 300 KRADS(Si) to show trends in device performance as a function of total dose. The test does not classify maximum radiation tolerance of the device, but simply offers designers insight to the critical parameter-shifts up to the specified total dose level. The MSK5977RH, MSK5976RH, MSK5953RH, and MSK5979RH all use the same active components. The data in this report is from direct measurement of the MSK5977RH response to irradiation but it is indicative of the response of all three devices and is applicable to all three devices.
■MIL-STD-883 Method 1019.7 and ASTM F1892-06 were used as guidelines in the development and implementation of the total dose test plan for the MSK 5977RH.
●Summary
■Based on the test data recorded during radiation testing and statistical analysis, the MSK5977RH, MSK5976RH, MSK5953RH, and MSK5979RH qualify as 300 KRADS(Si) radiation hardened. Set Pin Current and Line Regulation exhibited the most significant shift due to irradiation, however all performance curves stayed within specification up to 450 KRADS(Si) TID.

TTM Technologies

MSK5953RHMSK5976RHMSK5979RHMSK5977RHMSK5977VRH

More

Part#

RAD Hard Positive Adjustable Voltage Regulators

More

More

Test Report

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

October 16, 2014

219 KB

- The full preview is over. If you want to read the whole 16 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: