MSK 5950 RH RAD Hard Ultra Low Voltage Adjustable Positive Linear Regulator Total Dose Radiation Test Report

2022-11-10
●Introduction
■The total dose radiation test plan for the MSK 5950 RH series was developed to qualify the devices as RAD Hard to 300 KRADS(Si). The testing was performed beyond 300 KRADS(Si) to show trends in device performance as a function of total dose. The test does not classify maximum radiation tolerance of the device, but simply offers designers insight to the critical parameter-shifts up to the specified total dose level.
■MIL-STD-883 Method 1019.7 and ASTM F1892-06 were used as guidelines in the development and implementation of the total dose test plan for the MSK 5950RH.
●Summary
■Based on the test data recorded during radiation testing, the MSK5950RH qualified as a 300 Krad(Si) radiation hardened device. The test results were similar to the November 25, 2008 testing results. Feedback Voltage, Shutdown Threshold and Output Current Limit exhibited the most significant shift due to irradiation, however all performance curves stayed within specification up to 450 Krad(Si) TID.

TTM Technologies

MSK5950RHMSK5950RH series

More

Part#

RAD Hard Ultra Low Voltage Adjustable Positive Linear Regulator

More

More

Test Report

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

December 21, 2009

54 KB

- The full preview is over. If you want to read the whole 17 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: