CW32L031 CDM TEST REPORT(SH2201260098)
■CASE INFORMATION
▲Test Sample: CW32L031
▲LOT NO.: NA
▲Package: LQFP48
▲Quantity: 3 pcs
■DESCRIPTION OF TEST EQUIPMENT
▲Items: 1
▲Equipment/No.: 1606269
▲Model: ORION 3
■AMBIENCE CONDITION
▲Required temperature: 25+3 -5 °C
▲Required relative humidity: 55± 10 %RH
▲Actual temperature: 23.4~23.9°C
▲Actual humidity: 51.4~51.8% RH
■REFERENCE DOCUMENT
▲Items: 1
▲Standards: JEDEC EIA/JESD22-C101F
■TEST REQUIREMENT
▲2000V(±)x3pcs
▲TEST VOLTAGE:2000V(±)x3pcs
▲SAMPLE QUANTITY:3 pcs
▲FUNCTION TEST:by customer
▲FAILURE CRITERIA ( Reference Only ):±30% voltage shift at reference point before/after zapping
■TEST RESULTS
▲Discharge Pins All Pins
|
|
|
|