Glucose monitoring is a key link in diabetes management. Currently, there are two main methods for self-monitoring of glucose in patients with diabetes, one is traditional blood glucose Monitoring (BGM), and the other is continuous glucose monitoring (CGM). CGM can provide dynamic, comprehensive, and reliable whole-day glucose information to understand the trend of glucose fluctuations and find hidden hyperglycemia and hypoglycemia, thus becoming a new trend in glucose monitoring.


Principle and technical difficulties of CGM

CGM allows real-time monitoring of glucose concentration in subcutaneous tissue fluid by implanting glucose sensors. The sensor is the core component of a CGM system with high barriers, which directly determines whether the measurement results of the CGM system are accurate. Sensor electrodes, film layers, sensing layers, and calibration algorithm are also the key to determining the performance.


The CGM system measures the glucose concentration in interstitial fluid. Although there is a high correlation with glucose concentration, the difference between the two is not constant. There are great differences between concentration difference and the time to reach concentration equilibrium in different physiological states such as rest, post-meal, exercise, respiration, and hypoxia. In addition, factors such as electrode passivation and exotic reactant coating on the surface of the sensor will also cause the sensitivity of the sensor to change with the change of implantation time. In the actual application, environmental temperature, external pressure, and other factors can bring measurement errors.


The above problems can be solved by the calibration algorithm. In the calibration algorithm model, as an important variable, the ambient temperature or body surface temperature has an important impact on the effectiveness of the algorithm model.


NST1002 facilitates accurate CGM measurement

The NOVOSENSE NST1002 is a high-precision, low-power temperature sensor that can sense changes in ambient temperature or body surface temperature in real-time and adjust the algorithm accordingly to make glucose monitoring more accurate.

Structure design and installation position of temperature sensor NST1002 applied in CGM


In the actual application of CGM products, the structure design and installation position of NST1002 is also very particular. In terms of structure design, NST1002 can be close to the skin of the body surface to achieve accurate collection of body surface temperature, so as to provide more effective data.


With accumulated rich experience in surface temperature acquisition solutions, NOVOSENSE temperature sensors can help customers quickly complete product structure design and material selection. The flexible probe of the interstitial fluid glucose sensor is less than 0.4 mm in diameter and can be inserted 5mm below the skin to ensure accurate sensing of glucose concentration in the interstitial fluid outside the cells.