FSP850-50FGPH3 Meet 80 PLUS Platinum, RoHS Compliant 850 Watts FLEX Switching Power Supply
■PM Bus Revision 1.2.
■Active Power Factor Correction (PFC) meet EN61000-3-2
■High efficiency and reliability
■Compatible with European Union Directive 2011/65/EU & (EU)2015/863 (Restriction on Hazardous Substances).
■Remote ON/OFF function
■Internal 12V DC fan included
■Low noise and ripple
■Output over voltage, short circuit, and over current protection
■100% Hi-pot, ATE, and burn-in tested
■Re-settable power shut down
■Complies with FCC part 15 subpart J class B 115Vac operation, and CISPR 22 class B at 230Vac operation
■Approved by CB 62368 & 60950-1 2 nd , EMC. CUL/UL TUV, FCC
●Specification
■Temperature Range: Operating: 0°C ~ +50°C on full load; storage & shipping: -20°C ~ +80°C
■Humidity:
▲5~90%RH,Non-condending on operating.
▲5~90%RH,Non-condending on storage
■Dielectric Withstand: Primary frame ground 1800V AC for 2 second
■Efficiency: Typical > 92%
■Altitude: Applied for tropical Climates and use at altitudes not exceeding 5000M above sea level.
■Meet Energy Star 5.0 & ErP : The 5Vsb Standby efficiency is measured with the main outputs off (PS_ON# high state). Standby efficiency should be as shown in below table.
■Rise time: Less than 20ms
■Hold-up Time: 17 ms minimum at nominal input voltage for 75% maximum load.
■Power Good Signal: Power on delay time 100 ~ 500ms, off delay 1ms minimum (TTL and CMOS compatible)
■Leakage Current: Less than 3.5mA at 264Vac, 63Hz
■MTBF:A minimum predicted MTBF (MIL-HDBK-217) of 100,000 hours of continuous operation at +25°C.
■Dimensions (LxWxH): 220x81.5x40.5mm / 8.67x3.2x1.6inch
|
|