MSK6000RH RAD Hard High Side Driver With Current Sense Total Ionizing Dose Radiation Test Report
■The total dose radiation test plan for the MSK6000RH was developed to qualify the devices as RAD Hard to 100 KRADS(Si). The testing was performed beyond 100 KRADS(Si) to show trends in device performance as a function of total dose. The test does not classify maximum radiation tolerance of the device, but simply offers designers insight to the critical parameter-shifts up to the specified total dose level.
■MIL-STD-883 Method 1019.7 and ASTM F1892-06 were used as guidelines in the development and implementation of the total dose test plan for the MSK 196RH.
●Summary
■Based on the test data recorded during radiation testing and statistical analysis, the MSK6000RH qualifies as a 100 KRad(Si) radiation hardened device. IMON GAIN exhibited the most significant shift with irradiation. All other parameters stayed within pre-irradiation specification up to the maximum tested dose level of 300KRad(Si).
|
|
Test Report |
|
|
|