Synchronising Xsens Systems with Noraxon TeleMyo Step-by-step manual
The steps described below show how to make it possible for Xsens Awinda or Sync Station to send a signal (Awinda / Sync Station is Sync OUT and Noraxon is Sync IN) and how to receive the synchronization signal (Noraxon is Sync OUT, Xsens Awinda / Sync Station is Sync IN).
1.Perform the calibration and get both systems fully set.
2.Set the specifications for synchronization in both systems and connect sync cable(s)
3.Start the recording on the slave software. The slave software will wait for a trigger from the Master software to start recording.
4.Start the recording on the Master software. Then, both systems will start recording at the same time.
5.Stop recording on the master software. Then both systems will stop recording at the same time.
Depending on the type of synchronization performed different specifications are required for both systems. A detailed explanation of the different characteristics according to the desired synchronization are described below.
This document is written to synchronize the XSens Awinda system. However, most of the steps performed in the MVN software are the same for the MVN Link system. You can see the differences in the setup of the system in the last chapter of this document “Using MVN Link to synchronize”.
|
|
|
|