● To guarantee the performance specified in the ZSSC4175D Datasheet, every ZSSC4175D needs calibration. In the IDT production line, reference data is acquired for each chip and written into the User0 and User1 pages in the nonvolatile memory (NVM) of the ZSSC4175D. To apply the calibration, this reference data must be read in the sensor module production line, a calibration calculation must be executed (provided as a precompiled software library, DLL), and the calculated coefficients must be written into the chip NVM (together with the configuration).
● This Application Note describes how to use the IDT SSC4160D Application Graphical User Interface (GUI) to calibrate the ZSSC4175D. GUI revision ≥ V3.2.2 including DLL revision ≥ V3.3.0.0 must be used for this procedure.