Domestic Precision Op amps RS8538 Has Low Input Offset Voltage 1μv and the Temperature Drift 0.005μv/℃, Used for Signal Amplification of Electronic Sphygmomanometer
The basic principle of an electronic sphygmomanometer is to use a pressure sensor to detect vibration changes in blood flow and outputs to the MCU for algorithmic processing to obtain the blood pressure value. However, the output signal of the pressure sensor is relatively weak and requires a precision operational amplifier to handle it.
The output signal of the electronic sphygmomanometer sensor is very weak, so the front-end signal amplification is a very big challenge which asked the offset voltage and temperature drift characteristics of the amplifier to be as small as possible. Since the electronic sphygmomanometer is battery-powered, the power consumption of the amplifier is required to be low enough. For electronic sphygmomanometer sensor output signal amplification applications, we recommend the domestic precision op amp RS8538 of Runic, which adopts a CMOS process, rail-to-rail input, and output, with a high Gain-Bandwidth Product of 1.6MHz and an offset voltage as low as 1μV.
For single power supply or dual power supply from +2.5V (±1.25V) to +5.5V (±2.75V), the following is the electrical characteristic and Pin diagram of RS8538 precision op amp:
Table.1
Electronic sphygmomanometers generally use piezoresistive sensors to measure blood
vibration and output weak analog signals. If the op-amp has a large input offset voltage, it will cover up the real measurement signal. The RS8538 offset voltage is only 1μV, which can minimize the interference of the op-amp itself to the measurement signal. The temperature drift of Vos is 0.005μV/℃, which improves the accuracy and reliability of blood pressure measurement. Electronic sphygmomanometers are battery-powered and strictly require low system power consumption. The operating current of RS8538 is 340μA, and the low-power operational amplifier can extend the service life of the device.
Fig.1
In summary, Runic's single-channel high-precision operational amplifier RS8538 has the advantages of low input offset voltage, low Vos temperature drift, and low power consumption. At the same time, it is lower in cost. It is indeed a cost-effective solution used to amplify the sensor output signal in medical portable equipment such as electronic blood pressure monitors.
- +1 Like
- Add to Favorites
Recommend
- Runic‘s OP Amp RS8538and RS622, Low-Consumption LDO RS3236 Apply in Electronic Blood-Pressure Meter
- Runic Technology Launches Eleven Automotive-qualified ICs Meeting AEC-Q100 Grade 1 and MSL1
- Jiangsu Runic Technology Won 2021 China Analog Semiconductor Outstanding Business Award
- Runic Technology Participates in the 2021 ASPENCORE Double Summit
- The RS3005 Chip Developed by Runic Technology Helped The System MCU to Complete The Power Supply
- Runic‘s OP Amp RS622,Analog Switch RS2105 and Low-Consumption LDO RS3236 Apply in Finger Clip Oximeter
- Runic OP Amp RS8551, LDO RS3002 and RS3226 Series Apply in Hand-Held Infrared Thermometer Detector
- Runic Low-power LDO RS3221 Assists in the Design of Smart Home Sensors and MCU Power Supply, With Small Package Size and Low Quiescent Current as Low as 1μA
This document is provided by Sekorm Platform for VIP exclusive service. The copyright is owned by Sekorm. Without authorization, any medias, websites or individual are not allowed to reprint. When authorizing the reprint, the link of www.sekorm.com must be indicated.