How to Select Cooling Fan for Telecommunication Equipment?
When choosing right cooling fan for telecommunicaiton device, In addition to focusing on whether the air flow of the fan can meets the heat dissipation requirements of the device, We also need to pay attention to the Noise level.
The cause of the noise of the cooling fan is generally attributed to two points: No1 is the fan blade cutting air when rotating, called discrete noise . No2 when the air flow generated by the heat dissipation fan colliding with fanring , it is called broadband noise.
If the noise requirement of equipment is high, you need to minimize the noise from the above two reasons, For the noise generated by the fan blade rotation, the solution can start from US , Require our engineer to strengthen the design ability, and continue to optimize the design of high performance, low noise. and evaluate the accurate system characteristics in the early stage. Cooperate with the fa supplier, and select the heat dissipation fan in the high-efficiency working area of the system. To reduce boradband noise, the solution is to optimize the air duct of the communication equipment system and eliminate obstacles blocking the air intake of fans as much as possible.
Human wisdom is endless, Noise reduction cabinet, sound absorbing materials are also applied to noise reduction, to reduce the noise to the maximum.
Shenzhen HUAXIA HENGTAI Electronics Co.,Ltd is not only a collection of research and development, production, sales in one of the cooling fan manufacturers. They also provide the most cost-effective cooling faolutions, to answer your question, For your product running safty.
- +1 Like
- Add to Favorites
Recommend
- HXHT Launched the 254mm&200mm EC/AF Cooling Fan, Saving up 30% or Over Energy
- SANYO DENKI Develops 60×60×76 mm Cooling Fan San Ace 60L 9CRLB Type Featuring Remarkable 100,000-Hour Long Life of Continuous Operation
- SANYO DENKI Launches 140×140×38mm DC Fan with the Lowest Noise in the Industry,Suitable for Cooling Commercial Air Conditioners and Medical Equipment
- SANYO DENKI Has Developed a New Energy Saving ACDC Fan with the Industry‘s leading cooling performance with IP56 Option
- SANYO DENKI Launches 140×140×38mm DC Fan with the Lowest Noise in the Industry, Suitable for Cooling Commercial Air Conditioners and Medical Equipment
- Data Center Installations: In-Rack Cooling or In-Row Cooling?
- High-performance Thermoelectric Coolers Offer A Flexible Active Cooling Option for Spot Cooling of Lidar Sensors
- The Accomplishment of Mini Type Medical Water Cooling Block - Small in Size But with 400W Extraordinary Cooling Performance
This document is provided by Sekorm Platform for VIP exclusive service. The copyright is owned by Sekorm. Without authorization, any medias, websites or individual are not allowed to reprint. When authorizing the reprint, the link of www.sekorm.com must be indicated.