ISL3332, ISL3333 3.3V, ±15kV ESD Protected, Two Port, Dual Protocol (RS-232/RS-485) Transceivers DATASHEET
The ISL3332, ISL3333 are two port interface ICs where each
port can be independently configured as a single
RS-485/422 transceiver, or as a dual (2 Tx, 2 Rx) RS-232
transceiver. With both ports set to the same mode, two
RS-485/RS-422 transceivers, or four RS-232 transceivers
are available.
If either port is in RS-232 mode, the onboard charge pump
generates RS-232 compliant 5V Tx output levels from a
single VCC supply as low as 3.15V. The transceivers are
RS-232 compliant, with the Rx inputs handling up to 25V.
In RS-485 mode, the transceivers support both the RS-485
and RS-422 differential communication standards. The
receivers feature "full failsafe" operation, so the Rx outputs
remain in a high state if the inputs are open or shorted
together. The transmitters support up to three data rates, two
of which are slew rate limited for problem free
communications. The charge pump disables when both
ports are in RS-485 mode, thereby saving power, minimizing
noise, and eliminating the charge pump capacitors.
Both RS-232 and RS-485 modes feature loopback and
shutdown functions. Loopback internally connects the Tx
outputs to the corresponding Rx input, to facilitate board
level self test implementation. The outputs remain connected
to the loads during loopback, so connection problems (e.g.,
shorted connectors or cables) can be detected. Shutdown
mode disables the Tx and Rx outputs, disables the charge
pumps, and places the IC in a low current (35µA) mode.
The ISL3333 is a QFN packaged device that includes two
additional user selectable, lower speed and edge rate
options for EMI sensitive designs, or to allow longer bus
lengths. It also features a logic supply pin (VL) that sets the
VOH level of logic outputs, and the switching points of logic
inputs, to be compatible with another supply voltage in mixed
voltage systems. The QFN also adds RS-232 mode Tx EN
pins (DEN), and active low Rx enable pins (RXEN) to
increase design flexibility. In RS-485 applications, active low
Rx enable pins allow Tx/Rx direction control, via a single
signal per port, by connecting the corresponding DE and
RXEN pins together.
ISL3332 、 ISL3333 、 ISL3332IAZ 、 ISL3333IRZ 、 ISL333x |
|
3.3V, ±15kV ESD Protected, Two Port, Dual Protocol (RS-232/RS-485) Transceivers |
|
[ Gaming Applications ][ Slot Machines ][ Single Board Computers ][ Factory Automation ][ Security Networks ][ Industrial/Process Control Networks ][ Level Translators ][ Point of Sale Equipment ][ Dual Channel RS-485 Interfaces ] |
|
Datasheet |
|
ESD 、 IPC/JEDEC J STD-020 、 ISO9001 、 Pb-free 、 RoHS |
|
Please see the document for details |
|
|
|
|
|
28 Ld SSOP;40 Ld QFN |
|
English Chinese Chinese and English Japanese |
|
May 27, 2008 |
|
Rev 0.00 |
|
FN6362 |
|