EPA160025-P5-SZ linear adapter
●SPECIFICATIONS
■output voltage 16 V ac at 250 mA
■rated input voltage 120 V ac
■primary rated voltage 120 V ac 60 Hz 8 W
■primary exciting current 40 mA rms max.
■secondary rated voltage & current no load voltage (max.) 19.1 V,full load voltage (250 mA) 16 V ±5%
■temperature rise of primary winding (full load) 70°C max. using resistance method
■insulation resistance >= 100 M Ohm at 500 Vdc
■HI-POT test
▲primary to secondary 1240 V ac at 2 mA for 1 minute
▲primary to secondary 1600 V ac at 2 mA for 1 second
▲primary winding to secondary winding 1600 V ac at 2 mA for 1 second
▲primary winding to core 1600 V ac at 2 mA for 1 second
▲secondary winding to core 750 V ac at 2 mA for 1 second
■safety standard UL/cUL
■weight 218 g
■RoHS compliant yes
■test conditions ambient temp 40±2°C,humidity 90~95% 96 hours at Full Load
■adapter color case black,cord black,plug top black (insulation chip)
|
|