CIM12R 2.1 Multifunction Time Relays

2024-10-24
●Time data
■Timing functions: fig. 1 1: E 2: A, K, N, B1, S, LS 3: B, W
■Timing range: 50 ms ... 60 h
■Timing scale: 0.6 s / 6 s / 60 s / 6 min / 60 min / 6 h / 60 h
●Main circuit
■Number of outputs: 1 NO
■Output type: Triac, zero crossing
■Rated voltage: 250 V AC
■Switching at zero crossing: yes (td > 0.6 s)
■Rated current: 2 A
■Minimum load: 50 mA, 12 V
■Inrush current: 100 A, 10 ms
■Rated limit load: 78 A²s
■Typ. leakage current: 1 mA
■Rated load AC-1: 300 VA
■Mechanical endurance (cycles): ∞
■Electrical endurance at rated load AC-1 (cycles): ∞
●Control circuit
■Nominal voltage: 24 ... 240 V UC
■Operating voltage range: 16.8 ... 250 V
■Power consumption AC / DC: 1.2 VA / 430 mW
■Typ. input current on command input AC / DC: 22 / 22 mA
■Threshold voltage on command input AC / DC: 13 V / 15 V
■Rated frequency: 16 ... 63 Hz
●Insulation
■Rated test voltage control / main circuit: 2.5 kV rms / 1 min
■Pollution degree: 2
■Overvoltage category: III
●General data
■Ambient temperature storage (no ice): -40 ... 85 °C
Ambient temperature operation: -40 ... 70 °C
Conductor cross section: 2.5 mm², 2 x 1.5 mm²
Nominal screw torque: 0.4 Nm
Dimensions: fig. 2
Weight: 70 g
Protection degree: IP 20
Housing material: PC

Comat Releco

CIM12RCIM12R/UC...V

More

Part#

2.1 Multifunction Time Relays

More

More

Datasheet

More

More

Please see the document for details