AN1006: Differences Between Si534x/8x Revision B and Revision D Silicon
This document highlights differences between Revision B and Revision D silicon forthe following part numbers:
•Si5340
• Si5341
• Si5342
• Si5344
• Si5345
• Si5346
• Si5347
• Si5348
• Si5380
SUMMARY:
Compared to Revision B, Revision D silicon for Si534x/8x fixes several errata, supports higher maximum output frequency ranges, and offers several new features. This document outlines those differences.
Applies to Si5380/48/47/46/45/44/42/41/40:
With the release of Revision D for Si534x/8x, the Revision B devices are now classified as "Not Recommended for New Designs"(NRND). As of the Revision D release date, Silicon Labs has no plans to EOL the Si5348/47/46/45/44/42/41/40 Revision B devices and will continue production of both the Revision B devices and the newer Revision D devices. As of the Revision D release date, Silicon Labs does not plan to continue production of Si5380 Revision B devices. Customers using Si5380 must follow the instructions below to migrate their existing Revision B designs to Revision D.
Revision D devices are pin-compatible and footprint-compatible with Revision B devices. However, Revision D devices are not intended to be drop-in replacements for Revision B devices. As a result of changes to the circuitry in Revision D devices, their performance and behavior will not completely match that of Revision B.
• Customers currently using Si5348/47/46/45/44/42/41/40 Revision B in production may continue to do so. Silicon Labs will maintain production of both Revision B and Revision D concurrently.
• Customers who wish to migrate a design from Revision B to Revision D should download the latest version of ClockBuilder Pro and create a new custom OPN for Revision D with their desired configuration. Once a new Revision D OPN has been created, customers should verify functionality of the device in their system prior to starting production with Revision D.
• Silicon Labs does not recommend writing a register file, settings file, or regmap that was created for Revision B to a Revision D device. When migrating an existing design from Revision B to Revision D, customers should download the latest version of Clock-Builder Pro and create new register files, settings files, or regmap exports to be used with Revision D.
Si534x 、 Si538x 、 Si5340 、 Si5341 、 Si5342 、 Si5344 、 Si5345 、 Si5346 、 Si5347 、 Si5348 、 Si5380 |
|
|
|
|
|
Application note & Design Guide |
|
|
|
Please see the document for details |
|
|
|
|
|
|
|
English Chinese Chinese and English Japanese |
|
Revision D |
|
Rev. 0.1 |
|
AN1006 |
|
579 KB |
- +1 Like
- Add to Favorites
Recommend
All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.