SB5000 Series Shock Block GFCI

2023-06-28
●Description
■Special-Purpose Ground-Fault Circuit Interrupter (SPGFCI), Class C and Class D
▲The Industrial Shock Block® SB5000 series is a personnel protection device designed to meet the requirements for special- purpose GFCIs defined by UL 943C. This standard outlines GFCI classes specifically designed for use in industrial facilities. Class C GFCIs are intended to be used on three-phase systems where the line-to-line voltage is 480 V or less with a trip level of 20 mA, while Class D GFCIs are intended to be used on 600 V systems. The Industrial Shock Block includes DFT harmonic filtering, an automatic self-test feature, and is compliant to the UL 1998 Software in Programmable Components standard.
■Ground-Fault Circuit Interrupter (GFCI), Class A
▲The Shock Block is available as a 208 V Class A GFCI, allowing commercial kitchens, construction sites, and other non- dwelling units with wet areas to meet NEC 210.8(B) for their three-phase loads up to 100 A.
■Equipment Ground-Fault Protective Device (EGFPD)
▲Industrial Shock Block is also available with adjustable protection settings as an EGFPD. The EGFPD models can be set to trip at 6 mA or from 10–100 mA in increments of 10 mA. This offers more flexibility since GFCI devices are not allowed to have an adjustable trip level.
■Ratings and Models
▲Industrial Shock Block (GFCI & EGFPD) is available for three-phase voltages from 208 to 600 V with a maximum full load current up to 100 A. The power system can be either solidly or high resistance grounded, and the load must be three-phase without a neutral. The standard enclosure is IP 69K/NEMA 4X and outdoor rated, suitable for all industrial environments including high temperature washdown used in food production.
■Ground Wire (Load-Ground) Monitor
▲The Industrial Shock Block also monitors the ground wire (load ground) connection between the Industrial Shock Block and load. This is a required feature for Class C and D GFCI devices and is recommended for Class A GFCI and EGFPD devices.
▲If the ground-return path is broken, the Industrial Shock Block will trip and provide an alarm by changing the state of the alarm contacts. This monitoring circuit includes an extra wire (pilot wire) between the Industrial Shock Block and load. At the load, the pilot wire is connected to a termination device. The other end of the termination device is connected to the load ground (typically the enclosure).

Littelfuse

SB5000 SeriesSB5000SB5032-001-0SB5032-201-0SB5032-301-0SB5032-011-0SB5032-211-0SB5032-311-0SB5032-021-0SB5060-001-0SB5060-201-0SB5060-301-0SB5060-011-0SB5060-211-0SB5060-311-0SB5060-021-0SB5080-001-0SB5080-201-0SB5080-301-0SB5080-011-0SB5080-211-0SB5080-311-0SB5080-021-0SB5100-001-0SB5100-201-0SB5100-301-0SB5100-011-0SB5100-211-0SB5100-311-0SB5100-021-0SB5100SB5060SB5060 modelsSB5032SB5080

More

Part#

Shock BlockIndustrial Shock Blockpersonnel protection deviceIndustrial Shock Block®

More

people ]electrical equipment ]water ]Agriculture ]Amusement parks ]Commercial kitchens ]Construction ]Food ]beverage ]Horticultural lighting ]Maintenance shops ]Manufacturing ]Mining ]Oil ]gas ]Swimming pools ]Vehicle service centers ]Wastewater facilities ]

More

Datasheet

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

05/01/2023

1016 KB

- The full preview is over. If you want to read the whole 5 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: