LI0603 Reliability Test Report
●The samples were subjected to various reliability tests in accordance with the standard of the AEC-Q200 specification. The samples were measured according to its datasheet before and after the reliability tests. Pass of the qualification is defined as successful completion of the test requirements defined in Laird reliability test producure, and also there was no evidence of any physical or electrical degradation to the samples after test. Raw data is also included in the report and is provided to substantiate the results reported here.
●Per laird reliability test procedure, Laird can select one P/N from those parts with similar process, structure & performance to execute reliability test. So we select the LI0603D301R-10 as a representative from LI0603.
|
|
|
|