3FD-4XX PSD4-XX POWER TRANSFORMER Drawing

2022-09-15
■Electrical Specifications (@ 25℃)
●Maximum Power: 6.0VA
●Primary Voltage and Frequency: 115/230V 50/60Hz
●Secondary Voltage: See Table A
●Voltage Regulation: 18% TYP @ full load to no load
●Temperature Rise: 35℃ TYP (45℃ MAX allowed).
●Insulation Resistance:
▲100MΩ MIN @ 500VDC, Pri to Sec, Pri to Core
▲100MΩ MIN @ 500VDC ,Sec to Core
●Hi-Pot:
▲2500 Vrms 1 minute @ Pri to Sec
▲1500Vrms 1 minute @ Pri to Core
▲1500 Vrms 1 minute @ Sec to Core
▲500 Vrms 1 minute @ Sec to Sec
■Marking: TAMURA, Tamura part number (see sheet 2),MICROTRAN, Microtran part number (se sheet 2),date code, country of origin, safety logos and input and output ratings
■Safety:Insulation Class B (130°C) File No. E92957.CSA 22.2 No. 66-1988, File No. 069808.UL 1585, Class 2 or 3,Noninherently limited,File No. E95844.UL 506, General Purpose, File No. E91239.