■Electrical Specifications (@ 25℃)
●Maximum Power: 1.1VA
●Primary Voltage and Frequency: 115V 50/60Hz
●Secondary Voltage: See Table A
●Voltage Regulation: 24% TYP @ full load to no load
●Temperature Rise: 35℃ TYP (45℃ MAX allowed).
●Insulation Resistance:
▲100MΩ MIN @ 500VDC, Pri to Sec, Pri to Core
▲100MΩ MIN @ 500VDC ,Sec to Core
●Hi-Pot:
▲2500 Vrms 1 minute @ Pri to Sec
▲1500Vrms 1 minute @ Pri to Core
▲1500 Vrms 1 minute @ Sec to Core
▲500 Vrms 1 minute @ Sec to Sec
■Marking: TAMURA, Tamura part number (see sheet 2),MICROTRAN, Microtran part number (se sheet 2),date code, country of origin, safety logos and input and output ratings
■Safety:Insulation Class B (130°C) File No. E92957.CSA 22.2 No. 66-1988, File No. 069808.UL 1585, Class 2 or 3,Inherently limited,File No. E95844.UL 506, General Purpose, File No. E91239.

TAMURA

3FS-2XXPSS2-XX3FS-2103FS-2123FS-2163FS-2203FS-2243FS-2283FS-2363FS-2483FS-2563FS-2120PSS2-10PSS2-12PSS2-16PSS2-20PSS2-24PSS2-28PSS2-36PSS2-48PSS2-56PSS2-120