EDS Series Displacement Sensors – Installation and Operation Manual

2022-08-29
■General Remarks
●An ElastiSense EDS sensor may either be used as a standalone unit or as a part of a system together with other daisy chained sensors, which are controlled over a full duplex RS485 bus. The instruction provided here is limited to installation and operation of the sensor as a standalone unit.
●When operated as standalone displacement sensor, the EDS requires a 24VDC supply and outputs an analogue current in the range of 4-20mA. The signal is linearly proportional to the displacement i.e. 4mA corresponds to 0mm and 20mA represents the maximum displacement of the sensor.
●The sensor output can be customized to provide a voltage signal or a digital signal via RS485.