ElastiSense ApS, Bjerndrup Bygade 23, DK-6200 Aabenraa, Denmark - www.elastisense.com 001E5001 rev 3
4 – 20mA (1 – 5V or 2 – 10V on request)
Integer value in nm transmitted on full duplex RS485 network
-20°C to 80°C (Other ranges on request)
IP66 (at prescribed orientation)
Handling
To avoid damage to your sensors,
please refer to the images to the right.
Installation and connection
The sensor is delivered with an upper and a lower metal bracket with two mounting holes in each, as
shown in the specification section. The brackets are prepared for M5 screws for mounting (not
supplied). We recommend that a thread-locking product is used to prevent screws vibrating loose.
The sensor incorporates a highly stretchable strain gauge to measure displacement, and so operates
by being “stretched”. It is therefore necessary to mount the sensor with the distance between the
brackets holes being equal or greater than Dimension B shown in the table above. It is recommended
that the sensor is installed at 1mm stroke to cater for installation tolerances ensuring that the sensor
does not go below 0mm. STEP-files of the sensors at zero stroke are available on request.
A 24VDC supply voltage must be applied to the +24V and GND pins of the male M8 connector of the
EDS sensor, as shown on page 1.
Please take precautions to prevent over stroke during operation, as this may affect the accuracy of
the measurement and/or cause irreversible damage to the unit.
Warranty and Service
ElastiSense ApS products are warranted against defects in materials or workmanship. The warranty
applies for two years or 10 million cycles, whichever comes first. The warranty excludes impact
caused by strokes outside the rated measurement range. All faulty units must be shipped back to the
manufacturer for all warranty claims. Any service repairs must be performed by an authorized
ElastiSense ApS service partner. The unit contains no user serviceable components.