PXBCM-MB Power Xpert Branch Circuit Monitor
■For use with the Power Xpert Branch Circuit Monitor (PXBCM) Basic and Energy Code Series meter bases (MB)-Both the PXBCM-MB-BASIC meter base and PXBCM-MB-ENERGY meter base are designed to be used with the PXBCM-MME Meter Module External and/or-MMS Meter Module Strip.The Meter Base (MB) sources power to and collects data from the Meter Modules through the Meter Module Ports and Cables.
▲PXBCM-MMS-(L/R 9/15/21)-A Meter Module Strip
▲PXBCM-MME-X25-333MV Meter Module for External CTs
▲PXBCM-MME-X21-100MA Meter Module for External CTs
▲PXBCM-MMP-CBLnn/-CBLEnn Meter Module Port Cable and Cable Extension
■The PXBCM-MB is the data acquisition module/gateway of the PXBCM system.The PXBCM-MB aggregates the meter data from up to four PXBCM-MMS and PXBCM-MME meter modules.You can access the data from all channels (includ-ing virtual meters) through the RS485 COM1 or COM2 Modbus port using the RS-485 RTU proto-col,or the LAN Modbus TCP connection,or view it directly through the onboard web server.
■The Modbus address is set through a pair of rotary switches (Address H-L) on the front of the PXBCM-MB housing.Indicator lights show device status (Status) as well as communications sta-tus for both LAN Ethernet and COM1 or COM2 Modbus.A mode switch determines user access security levels.
■The PXBCM-MB must be housed in an appropriate NEMA or UL enclosure that ensures the device will remain within its specified environmental ranges and provides fire and mechanical protec-tion.In retrofit panel board applications the MB must be mounted in an enclosure external from the monitored assembly gear,unless the MB is an approved accessory for the panel board.
■Each Meter Module has the following LED Indicators
▲COM1 or COM2 Rx/Tx Green/Red LEDs–RS485 Modbus
▲MMP 1-4 Rx/Tx Green/Red LED–Meter Module Port communications
▲LAN Ethernet LEDs in RJ45 jack
◆Link Green on = Link Active,blink for TxRx
◆10/100 Speed - Amber off/on
▲Status Green/Red bicolor LED –
◆Green ~ 1Hz blink–Normal heart beat
◆Red–Application alarm
▲Com Status:Green/Red bicolor LED:
◆Green on=DHCP,Green off = Fixed IP
◆Red on=communications reset mode
PXBCM-MB-BASIC 、 PXBCM-MB-ENERGY 、 PXBCM-MB 、 PXBCM-MMS-(L/R 9/15/21)-A 、 PXBCM-MME-X25-333MV 、 PXBCM-MME-X21-100MA 、 PXBCM-MMP-CBLnn/-CBLEnn |
|
|
|