●CLASSIFICATION
■The product is a Class II device (enhanced insulation) and must be connected to the following leads:
▲Phase L1 (L) 120 V, Phase L2 (N) 0/120 V, Max. load 15 A (resistive load)The terminals are suitable for field wiring cables of 12 to 22 AWG. Heating element in accordance with the supply voltage.
●TECHNICAL DATA
■Supply :120/240 Vac 50/60 Hz
■Load :max. 15 A (resistive load)
■Power
▲1800 Wat120Vac
▲3120 W at 208 Vac
▲3600 W at 240 Vac
■GFCI : Class A (5 mA trip level)
■Temperature range : +5 to +40°C, +41 to +104°F
■Amb. temp. range : 0 to +25°C, +32 to +77°F
■WIFI : IEEE 802.11 b/g/n
■Contains FCC ID : 2ACSV-HF-LPT230
■Contains IC ID : 12243A-HFLPT230
■Construction of Control : Electronic room thermostat for regulating electrical underfloor heating.
■Method of Mounting Control : Independently mounted control for flush mounting
■Type of Action : Type 2.B.
■Rated Impulse Voltage : 2500 V
■Control Pollution Degree : PD2