Interroll Dynamic Storage – Pallet Flow Installation, Operating and Maintenance Instructions

2022-05-18
This instruction sheet will address “Accurate and proper installation”. The following tolerances are absolutely critical for good gravity flow results. These tolerances should be specified at the project development stage, included in the documentation for the installation pricing stage, included in the labor contract, reviewed at installation start up, and checked upon completion, prior to system sign off. We recommend the use of a transit or laser level to achieve these results.
● Rail must be installed at the specified slope for the application. The most common pitch used are 3/8” and 7/16” per foot, however refer to Interroll’s system drawing for the specific project or call Interroll for confirmation. The slope must not deviate from a true pitch line by more than 1/16”.
● Beams supporting the rail must be adjusted or shimmed so that rails within a lane do not deviate from level by more than 1/16”.
● Rails must be installed so that from front to rear of the system, the rail does not deviate from a true line by more than 1/16”.