N32G032F6U7 ESD (HUMAN BODY MODE)TEST REPORT (SH2011110088HE-CN)

2022-05-07
●TESTING LABORATORY IS APPROVEDED BY:
■IECQ Certificate of Approval No.: IECQ-L DEKRA 17.0004-01For Independent Test Laboratory According to ISO/IEC 17025
●WE HEREBY CERTIFY THAT:
■The test(s) shown in the attachment were conducted according to the indicating procedures. We assume full responsibility for the accuracy and completeness of these tests and vouch for the qualifications of all personnel performing them.
●DESCRIPTION OF UNIT
■MANUFACTURER: 国民技术股份有限公司
■DEVICE NAME: N32G032F6U7
■PACKAGED / PIN COUNT: UFQFPN20
■REFERENCE DOCUMENT:MIL-STD-883JMethod 3015.9Zap 3 pulse(s), Interval: 1.0 Sec
■TEST VOLTAGE: 2000V(±), 2500V(±), 3000V(±), 3500V(±), 4000V(±);
■SAMPLE QUANTITY: 18pcs
■FAILURE CRITERIA( Reference Only ): ±30% voltage shift at reference point before/after zapping
■Humidity at the test head: ≤30%RH