NS3603_2A ELECTROSTATIC DISCHARGE (ESD) TESTING REPORT (S200611064)
●Product: NS3603_2A
●Case NO: S200611064
●Quantity: 3 ea
●Test Item: CDM
●Package/Pin Count: LQFP80
●Application Date: 2020/6/11
●Date Finished: 2020/7/30
●Reference: ESDA/JEDEC JS-002-2018
●Temperature: 25 ± 5 °C
●Humidity: 55 ± 5%
●Test Instrument: Orion(SN1612241)
●Calibiration Due Date: 2019/09/13~2020/09/12
●Test Voltage: ±500V~±2000V, step :±500V
●Failure Criteria: After testing, DUT no longer fulfills requirements of ± 30% voltage drift at ± 1uA reference current and compliance within 10% V+I envelope around REFERENCE I-V curve (pre-zap).
●File Name of Raw Data: NS3603_2A
●ESD Testing Result: Minimum Pass Level = ±2000V
●NOTE 1:
■ESD/latch-up test is employed as one of qualification tests for electronic products. However, the pass / fail results of this test can NOT be taken as go/no-go criteria for IC tape-out and mass production. Before and after ESD/latch-up test(s),complete parametric and functional testing (F/T) are essential for determining pass/fail of the tested products. (References: Page 9, AEC-Q100-003-Rev-E-2003; and Page 15, ESDA-JEDEC JS-001-2017).
●NOTE 2:
■MA-tek sample storage policy is 14 days after the test data delivery. Prolonged storage can be arranged per client's request.
●WE HEREBY CERTIFY THAT:
■The test(s) was/were conducted according to test conditions provided by customer. Testing was performed on calibrated and JEDEC-ESDA qualified ESD instruments. The quality and comprehensiveness of this test(s) were delivered by qualified personnel.
|
|
|
|