HPC-1 emote control receiver User Manual
■Specifications
●Power Supply: 10-15VDC 10A - Reverse polarity protected. Not fused
●Output relays: 8A MAX switching current (total not to exceed MAX power input rating)
●Power consumption: <50mA
●Input power connection: 18 AWG 300V stranded MTW or
●equivalent. Output connection: 18 AWG 300V stranded MTW or
●equivalent. Switch settings: 1 momentary programming push
●button Momentary or Latching operation: Momentary only
●Shipping Weight: 1 lb
●Dimensions: 4.76 in (W) 5.00 (D) 1.17(H)
●Mounting instructions: 4 mounting holes .18 in diameter. Up to #8
●screw Environmental:
●Operating temp: 0-160
●degress F Not IP rated
●Accessories: RF340-2 transmitter, RF340 external antenna
●Applications: Optimized for remote control of hydraulic systems using 12VDC power supply
|
|