RENESAS VENTILATOR SOLUTION
The Covid-19 pandemic is has created havoc globally, putting more and more people in the hospitals. The demand of for ventilators is so high that our doctors are creating makeshift ventilators to meet the demand. Many companies are contributing to the cause in various ways, including opening up their IPs. Renesas is also helping this global cause, by designing ready-to-assemble electronic boards for ventilators. This is a ventilator system reference design to provide a portable ventilator used in hallway or non-ICU use cases. This machine can provide high pressure oxygen to patients in assist control and pressure control modes. The assist control mode provides a certain tidal volume of gas to a patient with each inhale. The flow sensor (FS1023) would monitor the gas flow rate at the inhale tube and the tidal volume would be calculated by the MCU using the rate integrated with time. The Oxygen valve would be controlled by the MCU and manage the oxygen ratio. The pressure control mode provides a certain pressure to the patient with each inhale There is one proximal air pressure sensor connected to the mask to monitor the inhale pressure and send that information to the RX23W. The blower, which provides pressure and blows air into the system, is driven by a motor control board controlled by the RX23T MCU and it uses I²C communication with the RX23W. To provide moist gas to patient, a humidifier is added to the system.
The system is using two MCUs for higher safety, so these devices can monitor and reset each other.
KEY FEATURES:
1.Secure system using two MCUs to monitor each other.
2.System available for Assist Control Mode and Pressure Control Mode.
3.Hardware is capable of providing low tidal volume, peak pressure, disconnect, and apnea alarms.
4.Both gas volume and flow rate are monitored by the FS2012.
5.The oxygen ratio is controlled by the valve, which is controlled by the MCU ,and monitored by the flow sensor.
6.The Exhale pressure is controlled by MCU through the exhale valve.
7.The Oxygen sensor is used to test FiO2 (fraction of inspired oxygen).
8.The Blower controlled via pressure/flow sensor feedback.
9.LCD brightness is controlled by the light sensor monitoring ambient light.
10.Battery balance monitor to extend battery lifetime.
- +1 Like
- Add to Favorites
Recommend
- New RX23W Module with Full Bluetooth® 5.0 Low Energy Support for System Control and Wireless Communication
- Renesas DSP Solution on Renesas Lab on the Cloud, Input Analog Signals Directly From A Signal Generator To The Rx231 Microcontroller Evaluation Board
- Experiencing the noise performance of the RX23E-A built-in delta-sigma ADC by using Renesas’ Lab on the Cloud
- Renesas Strategic Partners Presented Many of the RX MCU Solutions at ET & IoT Expo 2021
- Renesas Introduces 32-bit MCU RX23E-B with High-Speed, High-Precision Analog Front End for High-End Industrial Sensor Systems
- Renesas Proposes IO-Link for Temperature Controller Solution Based on 32-bit RX23E-A MCU
- Renesas Introduced Best-in-Class Analog Front End MCU RX23E-B with Built-in ΔΣA/D Converter for Industrial Sensors
- Renesas‘ Semiconductor Manufacturing Factory (Naka Factory) Fire: Production Capacity Has Recovered to 88%
All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.