●SENSATA'S PHILOSOPHY OF PROTECTION
■Reliable circuit protection is automatic protection which limits a fault to a single circuit. More importantly, it minimizes the danger of smoke and fire, not only in the equipment, but also in the conductors (or cables) leading to and from the equipment. Besides protecting the conductors, the protector must isolate the fault from the power source so that non-faulted circuits can continue functioning in a normal manner. These objectives may not always be achieved by a single protective device. To accomplish optimum protection, circuit designers must use the correct combination of devices, correct sizing of wire and safe routing to contribute to the overall circuit protection philosophy.
■The choice between circuit breakers, fuses, limiters or other protection means is governed by specifications, customer preference, maintenance, space, environmental restraints and circuit requirements. Proper selection procedures must result in a protective device with the lowest rating that will not open inadvertently. It must sense the fault, then disconnect the faulted line from the power distribution system before the wire insulation is destroyed. In addition, circuit breakers should almost always be trip-free, meaning that they cannot be held on against an overload. There are clear exceptions, such as in aircraft, when under certain conditions operation must be maintained in spite of overload. Besides considering all the variables involved, the time-current characteristics of the protective device should be compared with the time-current characteristics of the equipment (including starting or overload surges) component or wire.
■The entire electrical system, including the power source, wire (single or bundles), switching devices and equipment must be protected from faults. Generally, a circuit protector is used at any point in a circuit where the conductor size is reduced, unless the immediate upstream protector provides adequate protection for the smaller wire.
■Circuit components, such as transformers, rectifiers, filters, regulators and electronic circuits, have significantly different overload withstand characteristics from those of wire and cable. Many electronic circuits and components require extremely fast clearing devices, such as very fast acting fuses, to provide adequate protection from thermal damage.

AIRPAX

66006700IAR SeriesAP SeriesIPA SeriesIAG SeriesLEGA SeriesLEJ SeriesIAL SeriesLEL SeriesLELP SeriesIELR Series209 SeriesJAE SeriesMDS2 SeriesPGFM Series66F095-558867L090P-5588CER seriesIER1-1REC4C-52-20.0-AD-01-TT SeriesR SeriesPP SeriesPR SeriesCR SeriesCPP SeriesCPR SeriesT11-2-5.00A-01-11AL-VUP Series81541AP112AP12 -1-51-203-FMCPA SeriesIPAP -1 -1REC4 - 61- 10.0 - L - 01 - TIUG SeriesIEG SeriesCEG SeriesLEG SeriesIAGX SeriesIAGZX SeriesIUGX SeriesIUGZX SeriesIEGX SeriesIEGZX SeriesCEGX SeriesIAGBX SeriesIUGBX SeriesIEGBX SeriesCEGBX SeriesLEGBX SeriesCEGZX SeriesLEGZX SeriesIEGS SeriesIEGHS SeriesCEGS SeriesCEGHS SeriesLEGS SeriesLEGHS SeriesIEG1-1REC4-61-20.0- 01-VCUGZX SeriesSERIES TRIPLEGBXA66-1-62-20.0-AG-M6-TLMGH SeriesLEGH SeriesLMG SeriesLEGHZXA SeriesLEGBXA Series121-710-2450121-710-2451121-450-3000121-450-3001386-000-9030762-600-7651762-600-7650762-600-7654762-600-7653LEJBXA66-1-62-20.0-AG-M6-TLEJH SeriesLUJ SeriesLUJH SeriesLUJZXF SeriesLEJA SeriesBX SeriesZX SeriesIEL SeriesIUL SeriesIEL111IELH111IEL1111IELH1111LELHP SeriesCELHP SeriesCEL _ _ PCML _ _ PIEL1-1REC4-61-20.0-01-VLEL1-1REC4-61-20.0-01-VLELZXLMLZXCEL1-1REC4-51-20.0-A-01-VCMLBXCELBXCMLZXCELZXCMLHCML SeriesCELHCEL SeriesLELHPK11-1REC4-51-125.-A-01-VLELPKLMLPKLELZXPKLELBXPKLMLZXPKLMLBXPKLELHPKLMLHPKCELHPK11-1REC4-51-125.-A-01-VCELPCELHPCMLHPCELZXPCELBXPIELR1-1-61-20.0-01-VIALHRIULHRIELHRIALRIULRIELRIMLRIMLHR219 Series229 Series249 Series279 Series229D209-1-1-65-3-2-10-H-V249-6-C-20-30-30-2-62-1JRE SeriesJLE SeriesJLM SeriesJREP SeriesJRM SeriesJRMP SeriesJTE SeriesJTEP SeriesJTM SeriesJTMP SeriesJAEP SeriesJAM SeriesJAMP SeriesJLM-1-IREC4-51-1-F1-250-A-V273-8-B-T-1PGFM-110-B-A1IDLNK21-1REC5-38140-30-G1IDLNK21-1REC5-38140-30-G2IDLNK121-1REC5-39945-30-G1IDLNK21-1REC5-38140-50-G1IDLNK21-1REC5-38140-50-G2IDLNK121-1REC5-39945-50-G1PGFM-110-B-A1-188

More

Part#

Subminiature Bimetal Disc ThermostatsDIP, Subminiature Bimetal Disc ThermostatRoHS compliant, positive snap action, single pole/single throw, sub-miniature bimetallic thermostatSubminiature Bimetal Disc ThermostatMagnetic Circuit ProtectorsHydraulic Magnetic Circuit Protectorssnap-acting hydraulic-magnetic circuit breaker/protectorsnap-acting hydraulic-magnetic circuit protectorfully sealed, magnetic circuit protectorscircuit protectorhydraulic-magnetic circuit protectorsSINGLE POLE CIRCUIT PROTECTORMULTI-POLE CIRCUIT PROTECTORSPC BOARD MOUNTED CIRCUIT PROTECTORSROCKER CIRCUIT PROTECTORSLow-Depth, Hydraulic-Magnetic Circuit Breakerscircuit breakerHydraulic-Magnetic Circuit Breakerscircuit protectorsLELHP/CELHP CIRCUIT PROTECTORShigh current magnetic circuit protectorIALN/IULN PANEL SEAL CIRCUIT PROTECTORSRail-Mount Magnetic Circuit ProtectorsRail-Mount Hydraulic Magnetic Circuit ProtectorsModular Distribution SystemsGFCI Ground Fault Protection Sensing ModuleGFCI Sensing Moduleground fault or equipment leakage sensing device

More

printed circuit boards ]computers ]computer peripherals ]aircraft ]automotive ]test equipment ]thermal management applications ]power supplies ]PC boards ]rack mount applications ]wireless applications ]wired applications ]office appliances ]electronic data processing ]medical equipment ]business machines ]vending machines ]amusement machines ]medical instrumentation ]automotive production transfer lines ]communication ]navigation ]aircraft instrumentation ]radar ]petrochemical applications ]data processing ]broadcast equipment ]military applications ]power distribution units ]PDUs ]data center enclosures ]telecom AC power supplies ]Industrial applications ]drive motor systems ]telecommunication power systems ]peripherals ]telecommunications ]machine tools ]process control instrumentation ]branch circuit applications ]EDP ]air conditioners ]panel boards ]lighting controls ]telecommunication applications ]high current applications ]power bus system ]

More

Selection guide

More

More

Please see the document for details

More

More

DIP;SMT;TO-220;Y-220

English Chinese Chinese and English Japanese

September 2014

2455005000

26 MB

- The full preview is over. If you want to read the whole 244 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: