S27S Series Application Manual

2023-03-20

◆Overview
■S27S Series is a closed-loop type and through-type current sensor.
■The rated current is 300 A and the maximum current is ±500 A.
■This series has the input and output format of a connector type and variations as shown in table 1.
◆Characteristics
■Through-type supply system of the current to be measured.
■Closed-loop-type circuit configuration.
■Input/output of connector-type format with panel mounting structure.
■Power-supply voltage can be used in the range between ±12 V and ±20 V.
■Output in the form of current, given as 1/2000 of the current to be measured.
■Very high accuracy output current of within ±0.4%.
■Excellent output linearity of within ±0.1%.
■Fast response: Step response (response speed di/dt ) of less than 1 μs.
■Withstand voltage: AC 4000 V for 1 minute
■Satisfies conformity safety standard.

TAMURA

S27SS27S300D15YS27S300D15YM39-28-804038-00-62935566-04A-2106410-03C(102)S27S300D15□□

More

Part#

closed-loop type current sensorthrough-type current sensorcurrent sensor

More

Power monitoring equipment ]solar photovoltaic power generation ]generator ]

More

Application note & Design Guide

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

2018/05/17

797 KB

- The full preview is over. If you want to read the whole 20 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: