TR 1004 EN 0206 STABILITY TESTING CHOMERICS PREMIER™ CONDUCTIVE PLASTIC TEST REPORT

2022-06-10

●INTRODUCTION:
■ This document is written to report the stability testing of PREMIER conductive plastic materials. The primary tests performed are tensile strength and through resistance. The tests are performed after the material has undergone some environmental conditions for some period of time.
■ The tests performed are tensile testing per ASTM D 638: Standard Test Method for Tensile Properties of Plastics; and through resistance per Chomerics Document Number PRE-012: Through Resistance of Conductive Thermoplastics.
■ The environmental conditions consist of heat/humidity exposure at various temperatures and lengths of time, salt fog exposure, thermal shock and thermal cycling. Not all the materials are exposed to the same conditions.