What Are the Common Misconceptions in Vector Signal Analysis?
Common Misconceptions about Vector Signal Analysis Include the following:
Calibration Problem: Calibration of a vector network analyzer is a critical step in ensuring measurement accuracy. Common calibration methods include SOLT (Short-Open-Load-Thru) and TRL (Thru-Reflect-Line). However, it is easy for operators to fall into misconceptions when using these methods, such as incorrectly assuming that a “nice” calibration result means it is accurate, while ignoring the sources of error in the actual measurement.
Phase and Frequency Response Errors: The phase measurement function allows the VNA to accurately account for all sources of error, but directional errors, isolation errors, source and load errors, and so on, can affect measurement accuracy. For example, directional errors (ED) associated with signal leakage, isolation errors (ES) and reflection-related source mismatch errors, etc. can affect measurement results.
Operation Mistakes: Since vector network analyzers have multiple menu displays, misuse can lead to instrument dysfunction. Correct operation menu, especially the use of maintenance menu, can effectively eliminate soft faults.
Self-test error messages: The error messages appearing during the self-test of the instrument can help to locate the fault parts, but when the power-on self-test is normal and the instrument has hard faults, it is necessary to infer the fault parts through the function checking and the schematic block diagram.
The Basic Principle and Common Application Scenarios of Vector Signal Analysis:
Basic Principle: Vector signal analysis uses FFT (Fast Fourier Transform) and digital signal processing algorithms to replace the traditional analog IF part. It is able to process complex data, including amplitude and phase information, which allows it to provide more accurate measurements.
Application Scenario: Vector signal analysis is widely used in the RF and microwave bands, especially where high precision measurements are required. For example, in communication systems, vector signal analysis can be used for modulation domain analysis to help engineers diagnose and optimize system performance.
By understanding these misconceptions and principles, you can better use and maintain vector network analyzers to ensure the accuracy of measurement results.
- +1 Like
- Add to Favorites
Recommend
- Keysight Unveils First Midrange Network Analyzer Delivering Fast, Accurate Error Vector Magnitude Measurements
- Keysight, FormFactor, DMPI and VDI Join Forces to Deliver a New 170GHz/220GHz Broadband Vector Network Analysis Solution
- Keysight Introduces Software-Defined Handheld Analyzer N9912C
- Handheld DS2800 Spectrum Analyzer Incorporates Unique Test Capabilities that Ensure Proper Installation of Cable Networks and Reduce Service Calls
- What Is the Difference Between Vector Signal Source and Radio Frequency Signal Source?
- Exploring Vector Signal Generators
- Deviser Instruments Introduces the DS2831 Digital TV Spectrum Analyzer Family Enabling a Smooth Transition to OFDM and DOCSIS 3.1 HFC Networks
- Installation of UIY Surface Mounting Isolator/Circulator
This document is provided by Sekorm Platform for VIP exclusive service. The copyright is owned by Sekorm. Without authorization, any medias, websites or individual are not allowed to reprint. When authorizing the reprint, the link of www.sekorm.com must be indicated.