Nanochap Neurostimulation Chip Stim Engines ENS001 on Transcranial Electrical Stimulation Supporting Multi-channel Stimulation Integration in a Small Footprint
In recent years, the therapeutic effect of non-invasive brain stimulation has attracted widespread attention, and transcranial electrical stimulation, as one of the most commonly used techniques for non-invasive brain stimulation, has demonstrated a very promising application value in the treatment of neurological diseases. With the continuous development of this technology, the requirements for the product's minimum current regulation accuracy, output current accuracy, minimum PCB volume when core functions are realized, the types of waveforms that can be realized and the difficulty of controlling them, and the types of peripherals are getting higher and higher, and Nanochap responds to and solves these requirements with the ENS001 chip.
The Nanochap Stim Engines ENS001 programmable neurostimulation chip is a highly integrated programmable current stimulator. The chip integrates an ARM processor, an on-chip charging circuit, a configurable boost DC converter, an LCD screen driver, a 12-bit AD signal acquisition, a temperature sensor, and a multi-channel arbitrary current stimulation engine and other modules, which support arbitrary current waveform outputs from DC to above 250kHz, and at the same time, provide a single-channel current amplitude of up to 67mA, and support the merging of multi-channel currents.
Fig. 1 Block diagram of PCB design for ENS001 program
Nanochap Stim Engines Programmable Universal Stimulus Chip ENS001 Advantages and Features
●Highly integrated, simplifying customer material management
●Fine current control, each gear can only increase 33μA current, control accuracy ±16.5μA
●Up to 250 kHz sine/triangle/square or arbitrary waveform current stimulation.
●Multi-channel stimulation integration in a small footprint
●Charge balance technology, through the charge replication technology to maintain the positive and negative half-cycle charge close to equilibrium
●Strong scalability, support multiple channels in parallel to realize multi-mode stimulation.
Product Parameters
●Operating voltage range: 3-5V
●Operating Temperature: -40℃ ~ 85℃
●Low power consumption modes: sleep, stop, standby
●4,8,23-channel wide-range stimulation driver (10V ~ 60V)
●Core: ARM Cortex-M0 (32MHz)
Product Top Block Diagram
Fig.2
- +1 Like
- Add to Favorites
Recommend
- Nanochap Nerve Stimulation Chip Stim Engines ENS001 is Used in Foot Massagers to Customize Waveforms
- Nanochap Introduces Nerve Stimulation Chip Stim Engines Series ENS001 for Cochlear Implant, Charge Balance for Safety
- Nanochap Nerve Stimulation Chip ENS001 on Varicose Vein Treatment Instrument, Non-Invasive and Highly Effective Treatment
- Nanochap Neurostimulation Chip Stim Engines ENS001 in Electrical Stimulation Fitness Clothing, Integrated Solution Achieves Smaller Volume and Power Consumption
- Nanochap Neurostimulation Chip Stim Engines Series ENS001 Features Higher Precision and Stability in Foot Drop System
- Nanochap ENS001 Chip in Muscle Rehabilitation Instrument with Excellent Functionality and Flexible Stimulation Waveform Editing
- Nanochap Nerve Stimulation Chip Stim Engines ENS001 is Used in Female Physiological Period Analgesic Patch, Customized Waveforms to Meet the Different Needs of Customers
- Nanochap‘s ENS001 Neurostimulation Chip Is Used in Simulation Games to Provide More Realistic Somatosensory Feedback
This document is provided by Sekorm Platform for VIP exclusive service. The copyright is owned by Sekorm. Without authorization, any medias, websites or individual are not allowed to reprint. When authorizing the reprint, the link of www.sekorm.com must be indicated.