ANALOG DEVICES Low Power, Three Electrode Electrocardiogram (ECG) Analog Front End ADAS1000-3/ADAS1000-4

2022-09-09

●GENERAL DESCRIPTION
■The ADAS1000-3/ADAS1000-4 measure electro cardiac (ECG) signals, thoracic impedance, pacing artifacts, and lead-on/off status and output this information in the form of a data frame supplying either lead/vector or electrode data at programmable data rates. Its low power and small size make it suitable for portable, battery-powered applications. The high performance also makes it suitable for higher end diagnostic machines.
■The ADAS1000-4 is a full-featured, 3-channel ECG including respiration and pace detection, while the ADAS1000-3 offers only ECG channels with no respiration or pace features.
■The ADAS1000-3/ADAS1000-4 are designed to simplify the task of acquiring and ensuring quality ECG signals. They provide a low power, small data acquisition system for biopotential applications. Auxiliary features that aid in better quality ECG signal acquisition include: multichannel averaged driven lead, selectable reference drive, fast overload recovery, flexible respiration circuitry returning magnitude and phase information, internal pace detection algorithm operating on three leads, and the option of ac or dc lead-off detection. Several digital output options ensure flexibility when monitoring and analyzing signals. Value-added cardiac post processing is executed externally on a DSP, microprocessor, or FPGA.
■Because ECG systems span different applications, the ADAS1000-3/ADAS1000-4 feature a power/noise scaling architecture where the noise can be reduced at the expense of increasing power consumption. Signal acquisition channels may be shut down to save power. Data rates can be reduced to save power.
■To ease manufacturing tests and development as well as offer holistic power-up testing, the ADAS1000-3/ADAS1000-4 offer a suite of features, such as dc and ac test excitation via the calibration DAC and CRC redundancy testing in addition to readback of all relevant register address space.
■The input structure is a differential amplifier input thereby allowing users a variety of configuration options to best suit their application.
■The ADAS1000-3/ADAS1000-4 are available in two package options: either a 56-lead LFCSP or a 64-lead LQFP package; they are specified over −40°C to +85°C temperature range.
●FEATURES
■Biopotential signals in; digitized signals out
■3 acquisition (ECG) channels and one driven lead
■Can be ganged for 8 electrode + RLD using master ADAS1000 or ADAS1000-1
■AC and DC lead-off detection
■Internal pace detection algorithm on 3 leads Support for user’s own pace
■Thoracic impedance measurement (internal/external path)
■Selectable reference lead
■Scalable noise vs. power control, power-down modes
■Low power operation from 11 mW (1 lead), 15 mW (3 leads)
■Lead or electrode data available
■Supports AAMI EC11:1991/(R)2001/(R)2007, AAMI EC38 R2007, EC13:2002/(R)2007, IEC60601-1 ed. 3.0 b:2005, IEC60601-2-25 ed. 2.0 :2011, IEC60601-2-27 ed. 2.0 b:2005, IEC60601-2-51 ed. 1.0 b: 2005
■Fast overload recovery
■Low or high speed data output rates
■Serial interface SPI-/QSPI™-/DSP-compatible
■56-lead LFCSP package (9 mm × 9 mm)
■64-lead LQFP package (10 mm × 10 mm body size)

ADI

ADAS1000-3ADAS1000-4ADAS1000-3BSTZADAS1000-3BSTZ-RLADAS1000-3BCPZADAS1000-3BCPZ-RLADAS1000-4BSTZADAS1000-4BSTZ-RLADAS1000-4BCPZADAS1000-4BCPZ-RLEVAL-ADAS1000SDZEVAL-SDP-CB1Z

More

Part#

Low Power, Three Electrode Electrocardiogram (ECG) Analog Front End

More

ECG ]Monitor ]Diagnostic ]Bedside patient monitoring ]Portable telemetry ]Holter ]AED ]Cardiac defibrillators ]Ambulatory monitors ]Pace ]Maker programmer ]Patient transport ]Stress testing ]

More

Datasheet

More

More

Please see the document for details

More

More

LQFP;LFCSP_VQ

English Chinese Chinese and English Japanese

2018/01/02

Rev. B

D10997-0-1/15(B)

4.1 MB

- The full preview is over. If you want to read the whole 80 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: