E-LIGHT High energy ignition system
■Modular design with option for ionization flame monitor
■ATEX/IECEx certified versions available
●FEATURES
■High energy ignition
▲Ignition voltage 2,000 V for long cable routes
▲Ignition energy 2 joules per spark
■Modular and modern electronics
▲High energy ignition module and separate power supply
▲Thyristor controlled capacitor discharge
▲Microcontroller controls ignition
■Flexible operating voltages of 100 ... 240 VAC or 24 VDC (10 ... 30 VDC)
▲Customized solutions
■Optionally with ionization and/or start relay in one device/housing
▲Several ignition modules as well as PLC for monitoring of thermocouples and control tasks in one housing
▲Lower ignition frequency and continuous operation on request
E-LIGHT 、 E-LIGHT GUB03A ... 、 E-LIGHT ... EJB23 、 E-LIGHT … 162609 、 E-LIGHT … 233311 、 E-LIGHT … GUB03A 、 E-LIGHT … EJB23 |
|