FP Series FlowStream®
●General Description
■Laminar Flow Element differential pressure flowmeters are good for clean, dry, non-corrosive, noncondensing gasses. Corrected for temperature and pressure, it has a mass flow output. The analog (4-20 mA) output along with 2 programmable alarm set points make the meters suitable for process automation systems. NIST traceable and CSA units are Type 4 weatherproof. The accuracy is less than 1% of reading subject to limitations described in the Specifications section.
■The integrated LCD display can indicate flow rate or total as well as gas temperature and pressure.
■Calibration is done on air with empirically derived conversion factors. Oxygen cleaning optional.
■Sizes range from 1/8 to 3/4 inch threaded connections. Anodized aluminum is the standard material for the meter body and 316 Stainless Steel is available for use where external corrosion is a factor.
[ Burner Management ][ Leak Tests ][ Gas Consumption ][ Gas Blending ][ Shielding Gas ][ Laser Cutting ][ Die Casting ] |
|
Datasheet |
|
|
|
Please see the document for details |
|
|
|
|
|
|
|
English Chinese Chinese and English Japanese |
|
100620 |
|
|
|
FP 100620 |
|
562 KB |