MODEL 4042 Liquid Level Controller

2024-07-23

■DESCRIPTION

●The Model 4042 Liquid Level Controller monitors, displays and controls water level up to 34.6 feet, in a tank or reservoir.

●The Model 4042 operates from the 4-20mA input signal provided by the Time Mark Model 450 Pressure Transducer. This 4-20mA signal represents the water level to be controlled, where 4mA equals zero feet, and 20mA equals 34.6 feet. A liquid crystal display (L C D) is provided to show the water level during normal operation, and the setpoint values during calibration.

●There are four user-adjustable trip setpoints. As the water level rises above each trip point setting, the front panel L E D for that level illuminates, and the corresponding output relay energizes. A 4-20mA output, which tracks the 4-20mA input, is also provided. This signal output can be re-scaled to different ranges of level by the user.

●A test control, that simulates an input signal, is available on the front panel. The test control is useful for checking the trip setpoints, and overall system operation.

■Level simulator control

■Pressure transducer socket

■Output voltage for probe supply

■4 adjustable setpoints with relay outputs

■LCD level display with zero and span adjustments

Time Mark

MODEL 40424042

More

Part#

Liquid Level Controller

More

More

Datasheet

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

11/2011

1.1 MB

- The full preview is over. If you want to read the whole 6 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: