MODEL 4042 Liquid Level Controller
■DESCRIPTION
●The Model 4042 Liquid Level Controller monitors, displays and controls water level up to 34.6 feet, in a tank or reservoir.
●The Model 4042 operates from the 4-20mA input signal provided by the Time Mark Model 450 Pressure Transducer. This 4-20mA signal represents the water level to be controlled, where 4mA equals zero feet, and 20mA equals 34.6 feet. A liquid crystal display (L C D) is provided to show the water level during normal operation, and the setpoint values during calibration.
●There are four user-adjustable trip setpoints. As the water level rises above each trip point setting, the front panel L E D for that level illuminates, and the corresponding output relay energizes. A 4-20mA output, which tracks the 4-20mA input, is also provided. This signal output can be re-scaled to different ranges of level by the user.
●A test control, that simulates an input signal, is available on the front panel. The test control is useful for checking the trip setpoints, and overall system operation.
■Level simulator control
■Pressure transducer socket
■Output voltage for probe supply
■4 adjustable setpoints with relay outputs
■LCD level display with zero and span adjustments
|
|