PY-CIB054-00 PRIMERGY Server with iRMC S4 May Stop During POST or Malfunction While the OS is Running CUSTOMER INFORMATION BULLETIN
●PRIMERGY servers with iRMC S4 may stop during POST, or malfunction while the OS is running. The iRMC may also stop responding to IPMI, SSH, Telnet, and HTTP/HTTPS requests.
●If the issue occurs during BIOS POST, the boot screen stops at the Fujitsu logo, and displays “iRMC IP-Addr: --- unknown ---“ at the bottom of the screen.
■Cause:
●This problem is caused by firmware bugs in iRMC S4 firmware prior to 9.20F.
■Solution:
●Update iRMC S4 firmware to 9.20F or later.
●In case the issue occurs and the iRMC is not accessible, disconnect power cables, wait for three minutes, and re-connect power cables to power cycle the iRMC.
|
|
Supplier and Product Introduction |
|
|
|
Please see the document for details |
|
|
|
|
|
|
|
English Chinese Chinese and English Japanese |
|
September 1, 2020 |
|
REVISION 000 |
|
|
|
102 KB |
- +1 Like
- Add to Favorites
Recommend
All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.