This test measures the accuracy of the current sense amplifier circuit of the X3100. In the test, a known current is applied through a sense resistor to generate a voltage between the current sense inputs of the X3100. The analog output voltage of the X3100 is measured. This value (adjusted by the amplifier gain) is compared to the input voltage. The collected data includes the values from five devices from three different lots. The data also includes tests at 0°C, 25°C and 50°C and at each gain setting.