Series AE (electrical / visual-electrical, thread execution) CLOGGING INDICATOR
■The AE 30 and AE 40 pollution indicators are electrical differential pressure indicators.
■The AE 70 to AE 90 pollution indicators are combined optical and electrical differential pressure indicators. These differential pressure indicators can be fitted to all pressure filters (p ≤ 6000 PSI stainless steel, p ≤ 3200 PSI aluminium) for which there is a corresponding assignment on the relevant dimension drawing. As the degree of pollution of the filter element rises, so the difference between the entry pressure p1 and the exit pressure p2 of the filter increases.
■Depending on this pressure difference and irrespective of the operating pressure, in the pollution indicators:
◆AE 30 and AE 40, two electrical signals (contact maker/contact breaker) are triggered
◆AE 70, AE80 and AE 90, two electrical signals (contact maker/contact breaker) are triggered and two optical signals are formed.
■A metering piston subjected to the entry and exit pressure moves against a metering spring according to the pressure differential. Depending on the path, a permanent magnet integrated in the metering piston activates a reed contact (electromagnetic switch) and triggers the electrical signal. The electrical and optical indication is effected as a digital signal at the given switching pressure. Versions 70 to 90 of the pollution indicator are fitted with additional LED displays. The optical LED signal becomes visible according to the selected version in the translucent cover plate of the line box on the pollution indicator.
■In the pollution indicators
◆AE 70, AE80 and AE 90, the green LED signals the normal operating state (filter element not yet polluted to an unacceptable level), while the red LED signals that the filter element needs to be changed.
■The clogging indicators meet protection class 2 according to DIN EN 61140.
Series AE 、 AE.30.1,5.P.-.- 、 AE 30 、 AE 40 、 AE 70 、 AE 90 、 AE80 |
|
CLOGGING INDICATOR 、 pollution indicators 、 electrical differential pressure indicators 、 combined optical and electrical differential pressure indicators |
|
|
|
Datasheet |
|
|
|
Please see the document for details |
|
|
|
|
|
|
|
English Chinese Chinese and English Japanese |
|
06/22 |
|
|
|
1615 T |
|
226 KB |