IXIO/VIO: How to avoid cross-talk?
●IXIO next to IXIO
■All IXIO sensors have 2 frequency settings which can be set via LCD or remote control.Choose a different frequency for sensors mounted next to or opposite to each other in order to avoid cross-talk.
●VIO next to VIO
■When installing several VIO sensors, you have to activate the multi-mode to avoid cross-talk.To do so, choose the following configuration:
▲VIO-DT: select the presetting critical environment via DIP-switch 1 and 2.
▲VIO-ST: select frequency B for all VIO sensor (DIP 2 to ON).
●IXIO next to VIO
■When combining both sensor types, the best configuration to avoid cross-talk is:
▲IXIO on frequency A (inside) and B (outside)
▲VIO-ST on frequency B (multi-mode)
|
|