Senseair S8 LP Miniature CO2 sensor module with NDIR technique Product Specification

2022-10-31
●ltem: Senseair S8 LP Article No.004-0-0053
●Target gas: CO2
●Operating principle: Non-dispersive infrared (NDIR)
●Measurement range: 400-2000 ppm(Note 1). 0 to 10000 ppm extended range (Note2)
●Measurement interval: 4 seconds
●Accuracy: ±40 ppm ±3% of reading(Notes 3 and 4)
●Pressure dependence: +1.6% reading per kPa deviation from normal pressure
●Response time: 2 minutes by 90%
●Operating temperature: 0-50℃
●Operating humidity: 0-85% RH non condensed
●Storage temperature: -40-70℃
●Dimensions Max(LxW x H) [mm]: 33.9 x 19.8 x 8.7
●Weight: < 8 grams
●Power supply: 4.5-5.25 V unprotected against surges and reverse connection
●Power consumption: 300 mA peak, <18mA average
●Life expectancy: 15+ years
●Serial communication: UART, Modbus protocol(Notes 5). Direction control pin for direct connection to RS485 receiver integrated circuit.
●Alarm output, open collector: 1000/800ppm Normal state is Alarm state open conducting max 100 mA. Transistor open at CO2 High, OR Power Low OR at Sensor failure
●PWM output, 1 kHz:
■0-100% duty cycle for 0-2000 ppm
■3.3 V push-pull CMOS output, unprotected
●Maintenance: Maintenance-free for normal indoor applications with Senseair ABC ON
●Note 1: Sensor is designed to measure in the range 400-2000 ppm with specified in the table accuracy. Exposure to concentrations below 400 ppm may result in incorrect operation of ABC algorithm and shall be avoided for model with ABC on.
●Note 2: Sensor provides readings via UART in the extended range but the accuracy is degraded compared to specification in the table one.
●Note 3: In normal IAQ applications.Accuracy is defined after minimum three (3) ABC periods of continuous operation with ABC. However some industrial applications do require maintenance. Contact Senseair for further information
●Note 4: Accuracy is specified at room temperature +25℃ and at normal pressure 101.3kPa. Specification is referenced to certified calibration mixtures.Uncertainty of calibration gas mixtures(+1% currently )is to be added to the specified accuracy for absolute measurements.
●Note 5: See specification TDE2067 Modbus on Senseair S8

Senseair

Senseair S8 LP004-0-0053

More

Part#

Miniature CO2 sensor module

More

More

Datasheet

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

2022/4/29

Rev 15

PSP0126

1.7 MB

- The full preview is over. If you want to read the whole 9 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: