CGS-MF SGS TEST REPORT(TJIN1906009314MR)
■Sample Name : CGS-MF
■Above information and sample(s) was/were submitted and confirmed by the client. SGS, however, assumes no responsibility to verify the accuracy, adequacy and completeness of the sample information provided by client.
■Summary of Results:
●Test Item:IP6X
●Test Method:IEC 60529:1989+A1:1999+A2:2013 COR2:2015 and client’s requirement
●Test Requirement:No ingress of dust.
●Test result:After test, no dust entering.
●Conclusion:Pass
■Summary of Results:
●Test Item:IPX7
●Test Method:IEC 60529:1989+A1:1999+A2:2013 COR2:2015
●Test Requirement:Ingress of water in quantities causing harmful effects shall not be possible when the enclosure is temporarily immersed in water under standardized conditions of pressure and time.
●Test result:After test, no water entering.
●Conclusion:Pass
|
|
|
|