SEC-1212CE SEC-1223CE Switch Mode DC Power Supplies

2022-10-11
●COOLING (SEC-1212CE)
■SEC-1212CE is cooled by convection. PLACE THE SEC-1212CE UNIT IN A WELL VENTILATED OPEN AND COOL AREA. DO NOT BLOCK THE VENTILATION OPENINGS ON THE SIDES.
●Cooling & Fan Control/Thermal Shut Down (SEC-1223CE)
■SEC-1223CE is cooled by convection and forced air. A temperature controlled fan has been provided to improve cooling at higher loads. The fan is controlled by a sensor mounted on the power transformer. THE FAN WILL BE OFF AT LOWER LOADS. It will come on only when the temperature of the power transformer is ≥ 60ºC ± 5ºC / 140ºF ± 9ºF due to higher loads or higher ambient temperature or poor cool air circulation around the unit. The fan will switch off automatically at ≤ 40ºC ± 5ºC / 104ºF ± 9ºF. In case the fan fails or the air flow is blocked, a second temperature sensor mounted on the power transformer will activate over temperature shut down at ≥ 105ºC ± 5ºC / 221ºF ± 9ºF. The output voltage will be automatically resumed once the unit cools down to ≤ 75ºC ± 5ºC / 167ºF ± 9ºF. PLACE THE SEC-1223 UNIT IN A WELL VENTILATED OPEN AND COOL AREA. DO NOT BLOCK THE OPENINGS AT THE FAN DISCHARGE ON THE BOTTOM AND THE SUCTION OPENINGS ON THE SIDES .

SamlexAmerica

SEC-1212CESEC-1223CE

More

Part#

Switch Mode DC Power Supplies

More

More

User's Guide

More

More

Please see the document for details

More

More

English Chinese Chinese and English Japanese

2014/11/26

11001-SEC-1212CE-1223CE-1114

822 KB

- The full preview is over. If you want to read the whole 16 page document,please Sign in/Register -
  • +1 Like
  • Add to Favorites

Recommend

All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.

Contact Us

Email: