MHF II Connector QUALIFICATION TEST REPORT
■Testing was performed on the MHF II Connector to determine meets the requirement of I-PEX specification, PRS-2106.
●Conclusion
■All the specimen met the requirements of PRS-2106.
●Sample
■MHF II Plug Connector: P/N. 20686-001R-08
▲Cable: AWG#36 coaxial cable (jacket diameter 0.81mm)
■MHF III Receptacle Connector : P/N. 20279-001E-01 (Anti-static reel version)
▲Part No. 20279-001E-01、20279-001E-03、20279-001E-05 are different in the packing style
▲Only, so we tested part No. 20279-001E-01 as representative.
●Method
■Refer to product specification PRS-2106.
20686-001R-08 、 MHF II 、 20279-001E-01 、 20279-001E-03 、 20279-001E-05 、 MHF III |
|