TRIGGER PIN LUBRICANT Technical Bulletin

2022-06-15
●Products Affected:Panther, Cougar, SIGMA, OMEGA, MARK 3, LO-PRO, SECOBA SCBA,HIP PAC and SAR Second Stage Regulators.
●This technical bulletin supercedes technical bulletin number 110. Corrections or additions to this technical bulletin are in bold italics.
●NOTE
■This procedure need only be done on second stage regulators exhibiting sluggish response such as low flow or slow response characteristics.
■This procedure must be done when performing a standard six year overhaul.
■Regulators manufactured after October 19, 2001 have Molycote® 33 factory applied and will not have an “X” engraved after the serial number.
●This Technical Bulletin provides the information and procedures necessary to apply Survivair approved lubricant to the second stage trigger pin, part number 961521.